{"id":486,"date":"2025-12-08T08:27:47","date_gmt":"2025-12-08T08:27:47","guid":{"rendered":"https:\/\/airleakcontrol.com\/?p=486"},"modified":"2025-12-14T12:30:34","modified_gmt":"2025-12-14T12:30:34","slug":"tf11-appareil-de-test-de-fuite-simplicite-dintegration-et-clarte-operationnelle","status":"publish","type":"post","link":"http:\/\/airleakcontrol.com\/en\/tf11-appareil-de-test-de-fuite-simplicite-dintegration-et-clarte-operationnelle\/","title":{"rendered":"TF11 Leak Testing Device: Easy Integration and Operational Clarity"},"content":{"rendered":"<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8e8441bd wp-block-columns-is-layout-flex\" style=\"padding-right:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-left has-medium-font-size wp-block-paragraph translation-block\">The TF11 is a compact and versatile leak testing device, designed to meet industrial requirements while being perfectly suited for laboratory testing.\nThanks to its compact design, the TF11 easily integrates into machines and production lines, enabling minimal machine footprint without compromising performance.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-essential-blocks-slider  root-eb-slider-xq5gi\"><div class=\"eb-parent-wrapper eb-parent-eb-slider-xq5gi\"><div class=\"eb-slider-wrapper eb-slider-xq5gi\" data-blockid=\"eb-slider-xq5gi\" data-version=\"v4\" data-settings=\"eyJhcnJvd3MiOnRydWUsImFkYXB0aXZlSGVpZ2h0Ijp0cnVlLCJhdXRvcGxheSI6ZmFsc2UsImF1dG9wbGF5U3BlZWQiOjMwMDAsImRvdHMiOnRydWUsImZhZGUiOmZhbHNlLCJpbmZpbml0ZSI6dHJ1ZSwicGF1c2VPbkhvdmVyIjp0cnVlLCJzbGlkZXNUb1Nob3ciOjEsInNwZWVkIjo1MDAsInZlcnRpY2FsIjpmYWxzZSwiY3VycmVudFNsaWRlIjowLCJydGwiOmZhbHNlLCJyZXNwb25zaXZlIjpbeyJicmVha3BvaW50IjoxMDI1LCJzZXR0aW5ncyI6eyJzbGlkZXNUb1Nob3ciOjF9fSx7ImJyZWFrcG9pbnQiOjc2Nywic2V0dGluZ3MiOnsic2xpZGVzVG9TaG93IjoxfX1dfQ==\" data-arrownexticon=\"fas fa-arrow-alt-circle-right\" data-arrowprevicon=\"fas fa-arrow-alt-circle-left\" data-lightbox=\"false\"><div class=\"eb-slider-init eb-slider-type-image\"><div class=\"eb-slider-item content-1\" data-src=\"https:\/\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-11.png\"><div><img class=\"eb-slider-image\" data-lazy=\"https:\/\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-11.png\"\/><\/div><\/div><div class=\"eb-slider-item content-1\" data-src=\"https:\/\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-12.png\"><div><img class=\"eb-slider-image\" data-lazy=\"https:\/\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-12.png\"\/><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:52px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-essential-blocks-advanced-tabs alignwide  root-eb-advanced-tabs-o22kw\"><div class=\"eb-parent-wrapper eb-parent-eb-advanced-tabs-o22kw\"><div class=\"eb-advanced-tabs-o22kw eb-advanced-tabs-wrapper horizontal\" data-min-height=\"true\"><div class=\"eb-tabs-nav\"><ul class=\"tabTitles\" data-tabs-ul-id=\"eb-advanced-tabs-o22kw\"><li data-title-tab-id=\"1\" data-title-custom-id=\"\" class=\"active\"><div class=\"tab-title-wrap\"><h6 class=\"tab-title-text\">Description\u00a0:<\/h6><\/div><\/li><li data-title-tab-id=\"2\" data-title-custom-id=\"\" class=\"inactive\"><div class=\"tab-title-wrap\"><h6 class=\"tab-title-text\">Features<\/h6><\/div><\/li><li data-title-tab-id=\"3\" data-title-custom-id=\"\" class=\"inactive\"><div class=\"tab-title-wrap\"><h6 class=\"tab-title-text\">Secteur d\u2019activit\u00e9<\/h6><\/div><\/li><\/ul><\/div><div class=\"eb-tabs-contents\">\n<div class=\"eb-tab-wrapper\" data-tab-id=\"1\" data-tab-parent-id=\"eb-advanced-tabs-o22kw\"><div class=\"eb-tab-inner\">\n<p class=\"has-medium-font-size wp-block-paragraph translation-block\">The operating system has been designed for intuitive and fast programming:\n\nThe menu is streamlined and simplified, allowing test values to be entered with ease.\n\nA simple press of the M button quickly advances to the next setup step.\n\nCycle status and diagnostics are immediately visible to the operator:\n\nBlue Indicator: Signals the end of the test cycle.\n\nDual Indicator (Green\/Red): Provides immediate judgment (Pass or Fail).\n\nFull Display Screen: All critical information\u2014pressure, measured leak, test status, and final judgment\u2014is shown simultaneously.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"eb-tab-wrapper\" data-tab-id=\"2\" data-tab-parent-id=\"eb-advanced-tabs-o22kw\"><div class=\"eb-tab-inner\">\n<figure class=\"wp-block-table has-medium-font-size\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Display<\/strong><\/td><td>LCD screen, 4 lines \u00d7 20 characters<\/td><\/tr><tr><td><strong>Cycle Indicator<\/strong><\/td><td>Voyant bleu (Cycle en cours)<\/td><\/tr><tr><td><strong>Result Indicator<\/strong><\/td><td>Voyants bicolores (Rouge : Rejet, Vert : Conforme)<\/td><\/tr><tr><td><strong>Memory capacity<\/strong><\/td><td>Jusqu\u2019\u00e0 64 Programmes de test m\u00e9morisables<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table is-style-stripes has-medium-font-size\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><strong>Pressure Range<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Resolution ( leak )<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Uncertainty (Leak)<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Vide<\/td><td class=\"has-text-align-center\" data-align=\"center\">Vide<\/td><td class=\"has-text-align-center\" data-align=\"center\">+\/-1% + 1 digit<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0-500 mbar<\/td><td class=\"has-text-align-center\" data-align=\"center\">0-500 mbar<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identical<\/em><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0-2 bar<\/td><td class=\"has-text-align-center\" data-align=\"center\">0-2 bar<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identical<\/em><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0-7 bar<\/td><td class=\"has-text-align-center\" data-align=\"center\">0-7 bar<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identical<\/em><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table is-style-stripes has-medium-font-size\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><strong>Leak Range<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Resolution<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Uncertainty (Leak)<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">50 Pa<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,1 Pa<\/td><td class=\"has-text-align-center\" data-align=\"center\">+\/-1% + 1 digit<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">100 Pa<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 Pa<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identical<\/em><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">250 Pa<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 Pa<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identical<\/em><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">500 Pa<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 Pa<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identical<\/em><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table has-medium-font-size\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Operating Temperature<\/strong><\/td><td>+5 to +60 \u00b0C<\/td><\/tr><tr><td><strong>Storage Temperature<\/strong><\/td><td>-15 to +75\u00b0C<\/td><\/tr><tr><td><strong>Humidity<\/strong><\/td><td>Maximum 20% (non-condensing)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table has-medium-font-size\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Power Supply Required<\/strong><\/td><td>+24VDC (1.5 A minimum)<\/td><\/tr><tr><td><strong>Power Supply<\/strong><\/td><td>AC power adapter included<\/td><\/tr><tr><td><strong>Dimensions (H \u00d7 W \u00d7 D)<\/strong><\/td><td>120 x 300 x 200 mm<\/td><\/tr><tr><td><strong>Weight<\/strong><\/td><td>Approx. 7kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:34px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Maintenance and Accessories<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\"><strong>Entretien Recommand\u00e9 :<\/strong>\n<ul class=\"wp-block-list\">\n<li>V\u00e9rification et entretien annuel des composants pneumatiques.<\/li>\n\n\n\n<li>\u00c9talonnage annuel obligatoire pour la certification de pr\u00e9cision.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li class=\"has-medium-font-size\"><strong>Adaptable Accessories (optional):<\/strong>\n<ul class=\"wp-block-list\">\n<li>T\u00e9l\u00e9commande (2, 4 ou multifonction)<\/li>\n\n\n\n<li>Raccord \u00e0 prise int\u00e9rieur ou ext\u00e9rieur<\/li>\n\n\n\n<li>Fuite \u00e9talon<\/li>\n\n\n\n<li>Remote display<\/li>\n\n\n\n<li>G\u00e2chette<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/div><\/div>\n\n\n\n<div class=\"eb-tab-wrapper\" data-tab-id=\"3\" data-tab-parent-id=\"eb-advanced-tabs-o22kw\"><div class=\"eb-tab-inner\">\n<figure class=\"wp-block-table is-style-stripes has-medium-font-size\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Sector<\/strong><\/th><th><strong>Example Applications (Non-Exhaustive)<\/strong><\/th><\/tr><\/thead><tbody><tr><td>\ud83d\ude97 <strong>Automotive &amp; Transportation<\/strong><\/td><td>Composants moteurs (vases d\u2019expansion, filtres essence, pompes \u00e0 eau), bo\u00eetes de vitesses, valves de roue, pots d\u2019\u00e9chappement, injecteurs et raccords divers.<\/td><\/tr><tr><td>\ud83d\udd0c <strong>\u00c9lectrom\u00e9nager &amp; CVC<\/strong><\/td><td>Thermal Appliances (boilers, irons, coffee makers), Cooling Systems (refrigerators, air conditioners), Washing Machines, and Gas Stoves.<\/td><\/tr><tr><td>\ud83e\uddea <strong>Plastics &amp; Polymers<\/strong><\/td><td>Flaconnage (plastique), bouteilles, tuyauterie, bouchons de bouteille et raccords.<\/td><\/tr><tr><td>\ud83e\udd5b <strong>Verrerie<\/strong><\/td><td>Bouteilles de parfum, bouteilles en verre et contenants herm\u00e9tiques en verre.<\/td><\/tr><tr><td>\ud83d\udd29 <strong>Metals (Brass)<\/strong><\/td><td>Composants n\u00e9cessitant une \u00e9tanch\u00e9it\u00e9 critique : robinets de gaz, compteurs de gaz ou d&rsquo;eau, et pi\u00e8ces de raccordement en laiton.<\/td><\/tr><tr><td>\u2695\ufe0f <strong>Medical &amp; Pharmaceutical<\/strong><\/td><td>High-Sealing Requirement Devices: eye drop bottles, medical filters, syringes, blood bags, plastic taps, and micropipettes.<\/td><\/tr><tr><td>\ud83d\udce6 <strong>Packaging &amp; Processing<\/strong><\/td><td>Pressurized or Sealed Containers: ink cartridges, aerosols, various bottles, and plastic pouches.<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div><\/div>\n<\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-essential-blocks-button  root-eb-button-ni88f\"><div class=\"eb-parent-wrapper eb-parent-eb-button-ni88f\"><div class=\"eb-button-wrapper eb-button-alignment eb-button-ni88f\"><div class=\"eb-button\"><div class=\"eb-button-inner-wrapper\"><a class=\"eb-button-anchor\" href=\"https:\/\/airleakcontrol.com\/index.php\/contactez-nous\/\" rel=\"noopener\">Request a Demo<\/a><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p class=\"translation-block\">The TF11 is a compact and versatile leak testing device, designed to meet industrial requirements while being perfectly suited for laboratory testing.\nThanks to its compact design, the TF11 easily integrates into machines and production lines, enabling minimal machine footprint without compromising performance.<\/p>","protected":false},"author":1,"featured_media":770,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_eb_attr":"","_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[20],"tags":[],"class_list":["post-486","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-test-de-fuite"],"jetpack_featured_media_url":"https:\/\/i0.wp.com\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-11.png?fit=1080%2C1080&ssl=1","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"http:\/\/airleakcontrol.com\/en\/wp-json\/wp\/v2\/posts\/486","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/airleakcontrol.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/airleakcontrol.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/airleakcontrol.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/airleakcontrol.com\/en\/wp-json\/wp\/v2\/comments?post=486"}],"version-history":[{"count":15,"href":"http:\/\/airleakcontrol.com\/en\/wp-json\/wp\/v2\/posts\/486\/revisions"}],"predecessor-version":[{"id":883,"href":"http:\/\/airleakcontrol.com\/en\/wp-json\/wp\/v2\/posts\/486\/revisions\/883"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/airleakcontrol.com\/en\/wp-json\/wp\/v2\/media\/770"}],"wp:attachment":[{"href":"http:\/\/airleakcontrol.com\/en\/wp-json\/wp\/v2\/media?parent=486"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/airleakcontrol.com\/en\/wp-json\/wp\/v2\/categories?post=486"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/airleakcontrol.com\/en\/wp-json\/wp\/v2\/tags?post=486"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}