{"id":461,"date":"2025-12-08T07:59:18","date_gmt":"2025-12-08T07:59:18","guid":{"rendered":"https:\/\/airleakcontrol.com\/?p=461"},"modified":"2025-12-14T16:12:25","modified_gmt":"2025-12-14T16:12:25","slug":"cf11","status":"publish","type":"post","link":"http:\/\/airleakcontrol.com\/fr\/cf11\/","title":{"rendered":"CF11 : La R\u00e9f\u00e9rence Laboratoire pour le Contr\u00f4le en Continu"},"content":{"rendered":"\n<div class=\"wp-block-columns is-style-default is-layout-flex wp-container-core-columns-is-layout-001a5f59 wp-block-columns-is-layout-flex\" style=\"padding-right:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<div class=\"wp-block-column is-style-default is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-essential-blocks-slider  root-eb-slider-dulfc\"><div class=\"eb-parent-wrapper eb-parent-eb-slider-dulfc \"><div class=\"eb-slider-wrapper eb-slider-dulfc\" data-blockid=\"eb-slider-dulfc\" data-version=\"v4\" data-settings=\"eyJhcnJvd3MiOnRydWUsImFkYXB0aXZlSGVpZ2h0IjpmYWxzZSwiYXV0b3BsYXkiOmZhbHNlLCJhdXRvcGxheVNwZWVkIjozMDAwLCJkb3RzIjp0cnVlLCJmYWRlIjpmYWxzZSwiaW5maW5pdGUiOnRydWUsInBhdXNlT25Ib3ZlciI6dHJ1ZSwic2xpZGVzVG9TaG93IjoxLCJzcGVlZCI6NTAwLCJ2ZXJ0aWNhbCI6ZmFsc2UsImN1cnJlbnRTbGlkZSI6MCwicnRsIjpmYWxzZSwicmVzcG9uc2l2ZSI6W3siYnJlYWtwb2ludCI6MTAyNSwic2V0dGluZ3MiOnsic2xpZGVzVG9TaG93IjoxfX0seyJicmVha3BvaW50Ijo3NjcsInNldHRpbmdzIjp7InNsaWRlc1RvU2hvdyI6MX19XX0=\" data-arrownexticon=\"fas fa-arrow-alt-circle-right\" data-arrowprevicon=\"fas fa-arrow-alt-circle-left\" data-lightbox=\"false\"><div class=\"eb-slider-init eb-slider-type-image\"><div class=\"eb-slider-item content-1\" data-src=\"https:\/\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-1.png\"><div><img class=\"eb-slider-image\" data-lazy=\"https:\/\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-1.png\"\/><\/div><\/div><div class=\"eb-slider-item content-1\" data-src=\"https:\/\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-16.png\"><div><img class=\"eb-slider-image\" data-lazy=\"https:\/\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-16.png\"\/><\/div><\/div><div class=\"eb-slider-item content-1\" data-src=\"https:\/\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-17.png\"><div><img class=\"eb-slider-image\" data-lazy=\"https:\/\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-17.png\"\/><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\">\n<div style=\"height:64px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-left has-medium-font-size wp-block-paragraph\"><strong>La R\u00e9f\u00e9rence Laboratoire pour le Contr\u00f4le en Continu<br><\/strong>Le CF11 d&rsquo;Air Leak Control est un instrument de mesure haute pr\u00e9cision exclusivement<br>destin\u00e9 aux applications en laboratoire et \u00e0 la R&amp;D. Il a \u00e9t\u00e9 con\u00e7u pour offrir une plateforme de test compl\u00e8te et fiable, garantissant des r\u00e9sultats d&rsquo;une qualit\u00e9 m\u00e9trologique optimale.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:36px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-essential-blocks-advanced-tabs alignwide  root-eb-advanced-tabs-h0jsm\"><div class=\"eb-parent-wrapper eb-parent-eb-advanced-tabs-h0jsm \"><div class=\"eb-advanced-tabs-h0jsm eb-advanced-tabs-wrapper horizontal\" data-min-height=\"true\"><div class=\"eb-tabs-nav\"><ul class=\"tabTitles\" data-tabs-ul-id=\"eb-advanced-tabs-h0jsm\"><li data-title-tab-id=\"1\" data-title-custom-id=\"\" class=\"active\"><div class=\"tab-title-wrap\"><h6 class=\"tab-title-text\">Description<\/h6><\/div><\/li><li data-title-tab-id=\"2\" data-title-custom-id=\"\" class=\"inactive\"><div class=\"tab-title-wrap\"><h6 class=\"tab-title-text\">Caract\u00e9ristique<\/h6><\/div><\/li><\/ul><\/div><div class=\"eb-tabs-contents\">\n<div class=\"eb-tab-wrapper\" data-tab-id=\"1\" data-tab-parent-id=\"eb-advanced-tabs-h0jsm\"><div class=\"eb-tab-inner\">\n<p class=\"has-medium-font-size wp-block-paragraph\">Le CF11 regroupe au sein d&rsquo;un seul bo\u00eetier compact l&rsquo;instrumentation critique n\u00e9cessaire pour une caract\u00e9risation compl\u00e8te :<br>-Capteur de Pression<br>-Capteur de Temp\u00e9rature<br>-Double Capteur de D\u00e9bit (avec choix de gamme selon vos besoins sp\u00e9cifiques).<br>Le mode de test du CF11 s&rsquo;effectue de mani\u00e8re continue, permettant une surveillance et une analyse des donn\u00e9es sans interruption. Pour garantir une pr\u00e9cision maximale et la tra\u00e7abilit\u00e9<br>des r\u00e9sultats, l&rsquo;appareil int\u00e8gre un syst\u00e8me de protection thermique avanc\u00e9 :<br>Une protection int\u00e9gr\u00e9e contre les temp\u00e9ratures ambiantes trop \u00e9lev\u00e9es ou trop basses assure que la mesure est toujours effectu\u00e9e dans les meilleures conditions possibles.<br>Le CF11 est dot\u00e9 d&rsquo;une interface utilisateur simplifi\u00e9e et ergonomique. Sa conception intuitive rend sa manipulation ais\u00e9e, m\u00eame pour des protocoles de test complexes, permettant au personnel de laboratoire de se concentrer sur l&rsquo;analyse des r\u00e9sultats plut\u00f4t que sur le<br>param\u00e9trage de l&rsquo;instrument.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"eb-tab-wrapper\" data-tab-id=\"2\" data-tab-parent-id=\"eb-advanced-tabs-h0jsm\"><div class=\"eb-tab-inner\">\n<figure class=\"wp-block-table is-style-stripes has-medium-font-size\"><table><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u00c9chelle Pression<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>R\u00e9solution<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Incertitude (Fuite)<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">0-500 mbar<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,1 mbar<\/td><td class=\"has-text-align-center\" data-align=\"center\">+\/-1% + 1 digit<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0-5 bar<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 mbar<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identique<\/em><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0-10 bar<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 mbar<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identique<\/em><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table is-style-stripes has-medium-font-size\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u00c9chelle D\u00e9bit<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>R\u00e9solution<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Incertitude (Fuite)<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">1,20 l\/h<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,01 l\/h&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">+\/- 2,5% +1 digit<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">12 l\/h<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,1 l\/h<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identique<\/em><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">150 l\/h<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,1 l\/h<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identique<\/em><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2000 l\/h<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 l\/h<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identique<\/em><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">5000 l\/h<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 l\/h<\/td><td class=\"has-text-align-center\" data-align=\"center\"><em>Identique<\/em><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:19px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table has-medium-font-size\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Affichage<\/strong><\/td><td>\u00c9cran LCD 4 lignes de 20 caract\u00e8res<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table has-medium-font-size\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Temp\u00e9rature de Fonctionnement<\/strong><\/td><td>+5\u00e0 +60\u00b0C<\/td><\/tr><tr><td><strong>Temp\u00e9rature de Stockage<\/strong><\/td><td>-15 \u00e0 +75\u00b0C<\/td><\/tr><tr><td><strong>Humidit\u00e9<\/strong><\/td><td>20% maximum (sans condensation)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:37px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table has-medium-font-size\"><table><tbody><tr><td><strong>Alimentation requise<\/strong><\/td><td>+24VDC (1.5 A minimum)<\/td><\/tr><tr><td><strong>Fourniture<\/strong><\/td><td>Adaptateur d&rsquo;alimentation secteur inclus<\/td><\/tr><tr><td><strong>Dimensions (H x L x P)<\/strong><\/td><td>135 x 170 x 120 mm<\/td><\/tr><tr><td><strong>Poids<\/strong><\/td><td>Environ 2 kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:28px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Maintenance et Accessoires<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\"><strong>Entretien Recommand\u00e9 :<\/strong>\n<ul class=\"wp-block-list\">\n<li>\u00c9talonnage annuel obligatoire pour la certification de pr\u00e9cision.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li class=\"has-medium-font-size\"><strong>Accessoires Adaptables (en option) :<\/strong>\n<ul class=\"wp-block-list\">\n<li>Afficheur d\u00e9port\u00e9<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/div><\/div>\n<\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-essential-blocks-button  root-eb-button-k61gq\"><div class=\"eb-parent-wrapper eb-parent-eb-button-k61gq \"><div class=\"eb-button-wrapper eb-button-alignment eb-button-k61gq\"><div class=\"eb-button\"><div class=\"eb-button-inner-wrapper \"><a class=\"eb-button-anchor  \" href=\"https:\/\/airleakcontrol.com\/index.php\/contactez-nous\/\" rel=\"noopener\">Demander un Demo<\/a><\/div><\/div><\/div><\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>La R\u00e9f\u00e9rence Laboratoire pour le Contr\u00f4le en ContinuLe CF11 d&rsquo;Air Leak Control est un instrument de mesure haute pr\u00e9cision exclusivementdestin\u00e9 aux applications en laboratoire et \u00e0 la R&amp;D. Il a \u00e9t\u00e9 con\u00e7u pour offrir une plateforme de test compl\u00e8te et fiable, garantissant des r\u00e9sultats d&rsquo;une qualit\u00e9 m\u00e9trologique optimale.<\/p>\n","protected":false},"author":1,"featured_media":751,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_eb_attr":"","_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[21],"tags":[],"class_list":["post-461","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mesure-de-debit"],"jetpack_featured_media_url":"https:\/\/i0.wp.com\/airleakcontrol.com\/wp-content\/uploads\/2025\/12\/produits-air-leak-conttrol-1.png?fit=1080%2C1080&ssl=1","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"http:\/\/airleakcontrol.com\/fr\/wp-json\/wp\/v2\/posts\/461","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/airleakcontrol.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/airleakcontrol.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/airleakcontrol.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/airleakcontrol.com\/fr\/wp-json\/wp\/v2\/comments?post=461"}],"version-history":[{"count":20,"href":"http:\/\/airleakcontrol.com\/fr\/wp-json\/wp\/v2\/posts\/461\/revisions"}],"predecessor-version":[{"id":1000,"href":"http:\/\/airleakcontrol.com\/fr\/wp-json\/wp\/v2\/posts\/461\/revisions\/1000"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/airleakcontrol.com\/fr\/wp-json\/wp\/v2\/media\/751"}],"wp:attachment":[{"href":"http:\/\/airleakcontrol.com\/fr\/wp-json\/wp\/v2\/media?parent=461"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/airleakcontrol.com\/fr\/wp-json\/wp\/v2\/categories?post=461"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/airleakcontrol.com\/fr\/wp-json\/wp\/v2\/tags?post=461"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}